No. | Device Name | Picture | Index | Use |
---|---|---|---|---|
1 | Electronic universal testing machine | ![]() |
Maximum tension: 2000KN
|
Mechanical properties of stretching, bending, compressive strength test |
2 | Heat aging box | ![]() |
Temperature: -70 ~ 150 ℃
|
High and low temperature heat aging performance test |
3 | UV aging box | ![]() |
Temperature: 10 ~ 70 ℃
|
UV aging tests |
4 | Salt spray aging test machine | ![]() |
Test temperature: <63 ℃
|
Anti-aging properties of salt spray corrosion test |
5 | High temperature chamber | ![]() |
Maximum temperature: 500 ℃
|
High Temperature Performance Test |
6 | Resistance Tester | ![]() |
Resistance: 103-1012 Ohm
|
Resistance Test |
7 | X-ray nondestructive testing | ![]() |
Field: 100mm
|
NDT |
8 | Ultrasonic flaw detector | ![]() |
Detection range: 0.1-8000mm
|
NDT |
9 | Rockwell hardness | ![]() |
Digital
|
Hardness Testing |
10 | Universal friction and wear tester | ![]() |
Test force: 10-1000N
|
Friction and wear properties |
11 | Electro-hydraulic servo fatigue testing machine | ![]() |
Maximum load: ± 1000KN
|
Dynamic and static mechanical properties |
12 | Rotating bending fatigue testing machine | ![]() |
Runout: ≤0.01mm
|
Bending fatigue test |
13 | High-frequency fatigue testing machine | ![]() |
Maximum load: 500KN
|
Fatigue characteristics of the sample under tension and compression and alternating flowers and the sine wave |
14 | Electronic high-temperature creep rupture strength testing machine | ![]() |
Maximum load: 100KN
|
High temperature creep relaxation tests |
15 | Drop hammer impact test machine | ![]() |
Maximum impact energy: 30000J
|
Impact Performance Test |
16 | Low temperature impact test instrument | ![]() |
Temperature range: 30 ~ -60 ℃
|
|
17 | Thermal Mechanical Analyzer | ![]() |
temperature range:
|
Thermo-mechanical properties of materials |
18 | Dynamic Mechanical Analyzer | ![]() |
Frequency Range:
|
Tg test material |
19 | Laser thermal conductivity meter | ![]() |
temperature range:
|
Thermal diffusivity, thermal conductivity measurement |
20 | Dilatometer | ![]() |
temperature range:
|
Linear expansion coefficient measurement |
21 | Differential Scanning Calorimetry | ![]() |
temperature range:
|
Thermal performance |
22 | TGA | ![]() |
Resolution: 0.1 g
|
Thermal performance |
23 | Microscopic infrared absorption spectrometer | ![]() |
MCT single point detector: ≥7800-600cm-11
|
Particle and fiber analysis |
24 | Rotary flow analyzer | ![]() |
Frequency Range:
|
Rheological performance analysis |
25 | Elemental analyzer | ![]() |
Measuring range: C:0.03~20mg; H:0.03~3mg; N:0.03~2mg; S:0.03~6mg; O:0.03~2mg |
Content measurement sample CHNSO |
26 | Liquid X-ray diffractometer | ![]() |
High voltage stability: 0.005%
|
Microscopic observation |
27 | Nuclear magnetic resonance spectrometer | ![]() |
Time resolution: 12.5ns
|
Structural analysis of organic compounds |
28 | Fiber tensile tester | ![]() |
Load Range: 0 ~ 200 cN
|
Fiber strength, elongation test |
No. | Device Name | Picture | Index | Use |
---|---|---|---|---|
1 | Composite Interface Tester |
Experiment Temperature: RT ~ 400 ℃
|
Interfacial strength between the fibers, the contact angle, the fiber tensile strength | |
2 | Field emission scanning electron microscopy | ![]() |
Magnification: 10-650000 X
|
Microscopic surface morphology |
3 | Infrared Spectrometer | ![]() |
Wave number range: 7800 ~ 350cm-1
|
Structural Analysis |
4 | Gel Permeation Chromatography | |||
5 | Fineness instrument | ![]() |
Refractive Index range: 1.00-1.75 RIU
|
Molecular weight and distribution, aggregation morphology and molecular size of the polymer and aggregates, refractive index, etc. |
6 | Ultramicrotome | ![]() |
Precision slice thickness adjustable range 1nm ~ 15μm |
Samples sliced |
7 | XPS Spectrometer | ![]() |
Sensitivity: 16,000,000 cps
|
Chemical valence information elements, depth distribution, line scan, area scan analysis |
8 | ICP Spectrometer | ![]() |
Element detection limit:
|
Trace elements qualitative and quantitative analysis |
9 | Visible Spectrophotometer | ![]() |
Wavelength range: 320-1100nm
|
Liquid absorbance, transmittance, the concentration of the test |
10 | Electronic analytical balance | ![]() |
Maximum weight value: 120g Pan Dimensions: ?90mm Readability: 0.1mg Repeatability: 0.1mg Linearity error: 2s |
Samples weighing |